Operate installed heating and cooling equipment using normal controls when conditions permit. Record systems not operated and the reason, such as unsafe temperature or visible damage.

Visible corrosion, vent disconnection, combustion concerns and unsafe condensate disposal can justify prompt qualified evaluation. Do not state that combustion is safe without the testing and scope needed to support that conclusion.

Document the equipment, location, observed condition and practical significance. A functional response at one moment does not eliminate visible safety concerns.

Reporting method

1 Condition2 Significance3 Limitation4 Next action

Required field response

Apply what you learned

Prepare a condition-impact-recommendation narrative for heavy corrosion at a furnace vent connector.